VPA And VPAK Sterile Sampling Valves

The VPA and VPAK Series Sterile Sampling Valves are designed for safe, aseptic sampling in hygienic process environments such as pharmaceuticals, biotechnology, and food production. Featuring a compact, easy-to-clean design, these valves support CIP/SIP procedures and ensure contamination-free sampling. The VPA is ideal for general sterile sampling, while the VPAK offers enhanced features for demanding applications.

  • Radial Diaphragm (Silicone or Teflon)
  • Flush Mounted
  • CIP/ SIP
  • Easy Disassembly
  • Fully Autoclavable
ASEPTIC SAMPLING VALVES – VPA Series

MATERIALS OF CONSTRUCTION :

  • Body AISI 316L
  • Cover AISI 316L
  • Valve Stem AISI 316L
  • Valve cone AISI 316L
  • Radial Diaphragm – Silicone or PTFE
  • Spring AISI 304
  • Knob PTFE, autoclavable

OPERATING CONDITIONS :

  • Pressure = max. 8 bar
  • Temperature Range = -30°C to +150°C
  • Flow = max. 1.200 lt/hr @ (2 bar)

SURFACE FINISHES :

  • External Mirror Polish
  • Internal Mechanical Polish 240 Grit

ASEPTIC SAMPLING VALVES – VPAK Series

MATERIALS OF CONSTRUCTION :

  • Body AISI 316L
  • Cover AISI 316L
  • Valve Stem AISI 316L
  • Valve cone AISI 316L
  • Radial Diaphragm – Silicone or PTFE
  • Spring AISI 304
  • Knob PTFE, autoclavable
  • Tube AISI 316L

OPERATING CONDITIONS :

  • Pressure = max. 10 bar
  • Temperature Range = -30°C to +150°C
  • Flow = max. 400 lt/hr @ (2 bar)

SURFACE FINISHES :

  • External Mirror Polish
  • Internal Mechanical Polish 240 Grit
  • Bioreactors/ Fermentors
  • Sterile Holding Tanks
  • Blood/ Plasma Processing
  • WFI Storage
  • Media Preparation